Double Layer Lab Drying Oven Electric Vacuum Heat Chamber Vacuum Drying Oven
Application
Vacuum Drying Oven is widely used in biochemistry, chemical and pharmaceutical, health care, agricultural research, environment protection and other areas of research and application for powder drying, baking and all kinds of glass containers' disinfection and sterilization. Especially for those drying heat-sensitive, labile, oxidizing material and decompounded to carry on fast and effective drying process.
Standards Implement and Met
This type of product can meet the following criteria:
GB-2423.2-89(IEC68-2-2)Test B: High Temperature Test
GJB360.8-87(MIL-STD.202F) High Temperature Life Test
GJBl50.3(MIL-STD-810D) High Temperature Test
Specifications
1. Dedicatetouch and excellent user experience
2. Unique and compact design, top grade appearance, stable performance and easy operation
3. Can simulate a wide rang of temperature and humidity environments
4. Capable of testing large components, assemblies, and finished products
5. Customized sizes and configurations available
6. One year warranties
Model no | KOV-210A |
Air supply mode | Forced air circulation |
Temp Range | +50ºC ~ +200ºC |
Temp fluctuation | ±1.0ºC |
Heat up time | +50ºC ~ +250ºC About 70min |
Control mode | PID+SSR output |
Door Seal | Single door with silica |
Temperature controller
Sensor | High precision DIN A class,Dry ball φ4.8mm SUS #304 PT 100Ω |
Controller | Color touch screen controller with PID control |
Display function | Temp and humidity setting (SV) The actual (PV) value is displayed directly; Support executive program number, Paragraph, remaining time, number of cycles, running time display; Program editing and graphical curve display; Fixed point or program action status display; 7-inch resolution: 800 * 480, 65535 true color, LED backlight display screen. |
Control resolution | Temp: + 0.01ºC;Humidity: + 0.1%;time: 0.01min |
Setting range | Temp Condition:-100~200 ºC; According to the temperature of the chamer to adjust the working range (upper limit +5 ºC, lower limit -5 ºC) Humidity Condition:0~100 %RH |
Operating mode | Programmable running, constant running |
Program capacity | Running time up to 999999 h 59 m (also can be set to continue running without time limit); Available program capacity: up to 269 groups, a total of 13450 paragraphs; Usable memory capacity: 50 steps per group; Repeatable commands: Up to 32000 cycles per command |
Setting way | Man-machine dialogue mode, using touch input and control |
Communication Interface | RS-232,RS-485 and Ethernet. Data collection and curve display when connected with a computer Can be used as monitoring and remote control system Multi machines synchronization control available |
U Disk Memory Card | 1G-8G available for downloading historical curve and data, pluggable |
Photos show